Loading a clone, all the clone parameters are set on the receiver. The follow icon appears on the
right of the display indicating that a clone is loaded. The number and the name of the clone are
displayed on the top of the display menu and a brief list of the main parameters are displayed on the
status menu.
NOTE: the clones are saved on the EPROM and remains saved also after a reboot of the device.
NOTE: If a clone is loaded and then a reboot is executed, the MPR30-IEM always restarts with the
previous configuration (default clone).
NOTE: When a clone is loaded, it's not possible change the parameters
using Lithium battery, the power limit is set automatically to the max value permitted for no lithium
battery (that is 100mW).
Info
the INFO function shows many important features or information of MPR30-IEM receiver:
Frequencies range of working
MPR30-IEM Options
N= freq. range
470 ÷ 700 MHz
,
M= freq. range
566 ÷ 798 MHz
Number of errors.
If the number of errors is > 0 push SEL button to enter on the
Errors list. For each error a brief description and the error code is
showed. For more information, please see the Error List section.
* The Firmware Version recaps BL (Bootloader Version) and App (Application version).